id |
caadria2021_160 |
authors |
Ding, Jie and Xiang, Ke |
year |
2021 |
title |
The influence of spatial geometric parameters of Glazed-atrium on office building energy consumption in the hot summer-warm winter region of China |
source |
A. Globa, J. van Ameijde, A. Fingrut, N. Kim, T.T.S. Lo (eds.), PROJECTIONS - Proceedings of the 26th CAADRIA Conference - Volume 1, The Chinese University of Hong Kong and Online, Hong Kong, 29 March - 1 April 2021, pp. 391-400 |
doi |
https://doi.org/10.52842/conf.caadria.2021.1.391
|
summary |
To investigate the influence of the spatial geometric parameters of glazed-atrium on building energy consumption, this study established a prototypical office building model in the hot summer-warm winter region in China, and simulated the effect of energy consumption of six selected factors based on orthogonal experimental design (OED). Through the statistical analysis, the results showed that the floor height and the skylight-roof ratio were the most important parameters affecting the total energy consumption, with the contribution rates of 55.5% and 18.2%, followed by the section shape parameter and the plane orientation. In addition, the floor height and the section shape parameter were closely related to the cooling load and the lighting load, respectively, and both energy consumption could be reduced to a lower degree when the atrium inner interface window-wall ratio was 60%. Finally, the optimized parameter combination and energy-saving design strategies were proposed. This study provides architects with a simplified energy evaluation of atrium spatial geometric parameters in the early design stage, and it has an important guiding significance for the sustainable development of office buildings in the future. |
keywords |
Energy consumption; Spatial geometric factors; Glazed atrium; Office building; Hot summer–warm winter region |
series |
CAADRIA |
email |
|
full text |
file.pdf (9,451,763 bytes) |
references |
Content-type: text/plain
|
Aldawoud, A (2013)
The influence of the atrium geometry on the building energy performance
, Energy and Buildings, 57, pp. 1-5
|
|
|
|
Boubekri, M. and Anninos, W. Y. (1996)
Daylighting Efficiency of an Atrium: Part 1-The Four-Sided Type
, Architectural Science Review, 39(2), pp. 75-81
|
|
|
|
China Association of Building Energy Efficiency, CABEE (2019)
China energy consumption report
, architecture, 02, pp. 26-31
|
|
|
|
Fan, Z.Y. and Zhang, Y.H. (2020)
Numerical Investigation of key design parameters impact on energy consumption of commercial complex distributed atrium in cold area of China
, IOP Conference Series: Earth and Environmental Science, p. 012024
|
|
|
|
Ghasemi, M., Kandar, M. Z. and Noroozi, M (2016)
Investigating the effect of well geometry on the daylight performance in the adjoining spaces of vertical top-lit atrium buildings
, Indoor and Built Environment, 25(6), pp. 934-948
|
|
|
|
Laouadi, A., Atif, M. R. and Galasiu, A. (2002)
Towards developing skylight design tools for thermal and energy performance of atriums in cold climates
, Building and Environment, 37(12), pp. 1289-1316
|
|
|
|
Lu, Y.R. (2020)
Study on Energy Consumption of High-rise Office Buildings in Zhengzhou Based on Design Builder Simulation
, Journal of Shandong Agricultural University (Natural Science Edition), 51(02), pp. 355-359
|
|
|
|
Nasrollahi, N., Abdolahzadeh, S. and Litkohi, S. (2015)
Appropriate geometrical ratio modeling of atrium for energy efficiency in office buildings
, Journal of Building Performance, 6(01), pp. 95-104
|
|
|
|
Palma Rojas, D. (2014)
Atrium building design: key aspects to improve their thermal performance on the Mediterranean climate of Santiago de Chile
, International Journal of Low-Carbon Technologies, 9(4), pp. 327-330
|
|
|
|
Saxon, R. (eds) (1983)
Atrium Buildings: Development And Design
, Architectural Press, LONDON
|
|
|
|
Tabesh, T. and Sertyesilisik, B. (2016)
An investigation into energy performance with the integrated usage of a courtyard and atrium
, Buildings, 6(2), pp. 1-20
|
|
|
|
Vujoševiæ, M. and Krstiæ-Furundžiæ, A. (2017)
The influence of atrium on energy performance of hotel building
, Energy and buildings, 156, pp. 140-150
|
|
|
|
Wang, L., Huang, Q., Zhang, Q., Xu, H. and Yuen, R. K. (2017)
Role of atrium geometry in building energy consumption: The case of a fully air-conditioned enclosed atrium in cold climates, China.
, Energy and Buildings, 151, pp. 228-241
|
|
|
|
Zhang, Z., Li, W.Z. and Ying, X.Y. (2019)
Research on Parameterization for Shape of Standard Floor of Office Buildings under a Low-Energy Consumption Target
, South Architecture, 2019(01), pp. 76-81
|
|
|
|
Zhao, W., Kang, J. and Jin, H. (2017)
Influence Of Architectural Factors On Physical Environment In Atria
, Architecture Technology, 48(07), pp. 779-782
|
|
|
|
last changed |